436538/A
15
Turning on the cNODE MiniS 1.11-50V Ti
The transponder is designed for operation in water only. The transponder may be
operated in air for test purposes over a short period of time.
Prerequisites
The transponder must be charged before use.
Procedure
1
Connect the on/off plug to the end cap connector.
2
Tighten the locking sleeve to the end cap
connector.
Result
A buzz can be heard within 25 seconds as a confirmation that the transponder is activated.
Further requirements
It is recommended to test the transponder with the Test and Configuration unit (TTC) to
make sure the transponder is working properly before operation.
Connecting the transponder to external
power and responder signals
The transponder can also be used as a responder unit.
Prerequisites
The transponder must be charged before use.
Procedure
1
Use the cable with part number 402462 from Kongsberg.
2
Connect wire 6 and 8 in the pigtail (the ON/OFF function).