429468/B
11
Precautions to prevent Electrostatic Discharge (ESD)
Sensitive printed circuit boards and electronic modules must always be transported
and stored in protective antistatic packing bags. It as also important that they are not
transported or stored close to strong electrostatic, electromagnetic or radioactive fields. If
it is necessary to open and touch the printed circuit board or module inside the protective
bag, the following precautions must be taken.
1
For correct and safe handling of printed circuit boards and electronic modules, you
need a suitable working area. The working area must be covered by an approved
conductive service mat that has a resistance of between 50 kΩ and 2 MΩ, and is
connected directly to a reliable earth point via its earthing cord.
2
You - and all other service personnel involved - must wear a wristband in direct
contact with the skin. The wristband must be electrically connected to the service
mat.
3
Printed circuit boards and electronic modules must be placed on the conductive
service mat during installation and maintenance operations.
4
If, for any reason, it is necessary to move the circuit board from the conductive
service mat, it must be placed in an approved antistatic transportation container (for
example a static shielding bag) before transportation.
5
During installation and servicing, all electrical equipment (for example soldering
irons and test equipment) must be earthed.
Installing the cNODE Embed cables
The cables can be provided with an optional cable kit.
Prerequisites
The following specific items are required for this task.
• 1 x Molex 4–pin receptacle 43025-0400
• 1 x Molex 8–pin receptacle 43025-0800
• 1 x Molex 10–pin receptacle 43025-1000
• 14 x Molex Female crimp terminal 43030-0008
If you have a cable kit, the wires are already connected to the connectors.
Procedure
1
Connect the transducer cable.
Installing the transducer cables TD80V, page 13
Installing the transducer cables TD180, page 12
Summary of Contents for cNODE Embed
Page 1: ...429468 B October 2020 Kongsberg Maritime AS cNODE Embed Instruction Manual ...
Page 4: ...4 429468 B cNODE Embed TD180 wiring diagram 33 cNODE Embed ...
Page 29: ...429468 B 29 TD80V Outline dimensions Drawing file ...
Page 30: ...30 429468 B TD180 Outline dimensions cNODE Embed Instruction Manual ...
Page 31: ...429468 B 31 PCB Outline dimensions Drawing file ...
Page 32: ...32 429468 B cNODE Embed TD80V Low wiring diagram cNODE Embed Instruction Manual ...
Page 33: ...429468 B 33 cNODE Embed TD180 wiring diagram Drawing file ...
Page 37: ......
Page 38: ... 2020 Kongsberg Maritime ...