Message explanations
A-34
385585/C
Maximum number of drivers are reached
Description:
This message shall not occur during normal operation, but is intended to be an aid
for the software engineer during configuration/commissioning.
Corrective
actions:
Should the message occur during normal operation, contact Kongsberg Maritime
service.
Message receive error or no read/write func.
Description:
This message shall not occur during normal operation, but is intended to be an aid
for the software engineer during configuration/commissioning.
Corrective
actions:
Should the message occur during normal operation, contact Kongsberg Maritime
service.
Midships as rotation center
Description:
This message is reported if the operator has selected center of gravity as rotation
center. The method of detection is by a software check on Surge/Sway offset
difference.
Additional
information:
•
Surge offset from CG (Centre of Gravity, i.e. 0.0)
•
Sway offset from CG (i.e. 0.0)
Corrective
actions:
An operative advice is to ensure that the position deviation is zero at the moment
of applying the new rotation center.
Module group table overflow
Description:
Configuration error. Too many module groups.
Possible
consequences:
State summaries such as alarm count etc. will not be correct.
Corrective
actions:
Increase the MaxGroups parameter in the Module Groups section in the PS
configuration (.ps file).
Monitor VRS out of limits heave/pitch/roll
Description:
This message is reported if the measured value (defined by the last word in the
message title) is outside the warning or alarm limit.
The last word in the message title can be:
Roll
Pitch
Heave
The reason for the fault may be environmental conditions or a fault in the sensor.