Message explanations
385585/C
A-15
Draught [#] sensor rejected
Description:
The difference between the value received from the sensor and previous values
received exceeds limit and the sensor is rejected.
The data from this sensor will now be "frozen" to the last legal value. The sensor
value will again be updated from measurement if
•
The measurement is within legal range
•
The sensor is disabled and then enabled
Additional
information:
Measured value (meters).
Used value (meters)
Possible
consequences:
•
Data from this sensor is "frozen" and is no longer updated from
measurements.
•
If only one draught sensor is enabled, the used draught will be frozen. DP
will loose dynamic update of draught data
Corrective
actions:
If only one draught sensor is enabled, manual draught input or predefined
draughts should be used.
If other draught sensors are available, disable the failed sensor.
Driver configuration is not available
Description:
This message shall not occur during normal operation, but is intended to be an aid
for the software engineer during configuration/commissioning.
Corrective
actions:
Should the message occur during normal operation, contact Kongsberg Maritime
service.
Driver operation is not available
Description:
This message shall not occur during normal operation, but is intended to be an aid
for the software engineer during configuration/commissioning.
Corrective
actions:
Should the message occur during normal operation, contact Kongsberg Maritime
service.
Driver status is not available
Description:
This message shall not occur during normal operation, but is intended to be an aid
for the software engineer during configuration/commissioning.
Corrective
actions:
Should the message occur during normal operation, contact Kongsberg Maritime
service.