Kongsberg cJoy OT
Displayed VRS information
You can examine the status and measured values for the vertical reference sensor on the
Sensor view (see
on page 38).
Enabling the VRS
To enable the VRS, proceed as follows:
1
Display the Sensor Enable input dialog.
2
Check that the colour of the
Ready
field for the VRS is green.
3
Move the focus to the
Enable
field for the VRS and change the option to
On
.
4
Press the
Enter
button.
• The VRS is enabled.
5
Close the Sensor Enable input dialog.
Disabling the VRS
To disable the VRS, proceed as follows:
1
Display the Sensor Enable input dialog.
2
Move the focus to the
Enable
field for the VRS and change the option to
Off
.
3
Press the
Enter
button.
• The VRS is disabled.
4
Close the Sensor Enable VRS input dialog.
Faulty VRS
If measurements from the VRS are not accepted by the system, or if at least one of
the channels for the VRS is faulty, a message is displayed with information about the
failure, for example:
VRS 1 not ready
When the VRS has been repaired and is ready for use, you should enable it again.
Speed sensors
Speed measurements can be used as an addition to position measurements to improve
the vessel speed control.
The speed information may be received from two sources, Doppler Log and GPS speed
sensors. You can select available speed sensors or enter a manual alongships vessel
speed value.