Komshine KOC-250 Instructions Download Page 1

KOC-250 Optical Fiber Cleaning Pen Instructions

External function description

1

2

4

Connector inside adaptor

3

Connector plugs alone

 

n

o

it

c

n

u

F

 

e

m

a

N

 t

r

a

P

 .

o

N

A

 .

e

c

a

d

n

e

 r

e

t

c

e

n

n

o

c

 l

a

c

it

p

o

 

e

h

o

h

t

o

l

c

 

g

n

i

n

a

e

l

c

 

e

h

d

a

e

L

 

p

i

T

B

Nozzle 

Lead tip to the optical connecter end face.
Push the button to extend and contract the nozzle.
Push the outer shell to clean the connector. 
Acts as dust cap or cleaning adapter for connector plug. 
Provides indication of remaining cleaning cloth.

C

Lock Button 

D

Outer Shell

E

Guide Cap

F

Indicator

Standard Mode 

Extended Mode 

C. Lock Button 

D. Outer Shell 

Push Lock Button 

Pull Nozzle 

A. Tip 

B. Nozzle 

E. Guide Cap 

F. Indicator 

Pull Nozzle while   

pushing lock button. 

(White) 

Cloth 

Red 

Red 

Tip (Black) 

Cloth (White)

No Cloth 

(Black) 

(White) 

Cloth 

Tip (Black) 

View of Indicator 

View of the Nozzle end 

Full

Little 

Empty 

1. Remove Guide Cap from the device. 

2. Insert tip of cleaner into SC Adaptor.

3. Push the Outer Shell to start cleaning the 

SC connector end face.    A “click” sound 

indicates end of cleaning process.    Close the 

cover after use. 

Be careful not to slant the Cleaner SC while inserting 

into the adapter.   
Do not overly exert force during insertion as this may 

cause damage to both the connector and the Cleaner SC.  
If pushing Outer Shell is inhibited, remove 

Cleaner SC from adapter and ensure 

that there is no sizeable debris inhibiting the cleaning 

process. 

CLICK !! 

Guide Cap 

Standard Mode

Extended Mode 

SC Adaptor 

Note: This drawing shows only SC, but this product can clean ST and FC too. 

1. Open the Cover on the Guide Cap. 

         

2. Insert SC connector into the Guide Cap. 

3. Push the Outer Shell to start cleaning the 

SC connector end face.    A “click” sound 

indicates end of cleaning process.    Close the 

cover after use. 

Be careful not to slant SC connector while inserting 

into the Guide cap. 
Do not overly exert force during insertion as this may 

cause damage to both the connector and the Cleaner SC.  
If pushing Outer Shell is inhibited, remove 

Cleaner SC from adapter and ensure hat there is no 

sizeable debris inhibiting the cleaning process.   

SC Plug 

Guide Cap 

Cover 

CLICK !! 

Push straight. 

Note: This drawing shows only SC, but this product can clean ST and FC too. 

Identification of remaining cloth 