2.2. Standard operating modes
4 standard operating modes are available on your air handling unit. Each operating mode has preset air volume and
desired temperature values:
AWAY
NORMAL
INTENSIVE
BOOST
Ventilation
intensity
20%
50%
70%
100%
Set
temperature
20°C
20°C
20°C
20°C
These settings may be changed (see “Control and Settings”).
2.3. Special operating modes
4 special operating modes are available on your air handling unit. During activation, KITCHEN, FIREPLACE and OVERRIDE
modes are set for operation from 1 min. to 300 min. In HOLIDAY mode, operation time is set from 1 to 90 days or for a specific
date. OVERRIDE mode may also be activated by short-cutting designated terminal on the main board, i.e. by connecting a
switch, cooker hood or a motion sensor (see “Installation Manual”). Each operating mode has preset air volume and desired
temperature values:
KITCHEN
FIREPLACE
OVERRIDE
HOLIDAYS
Intensity
of supplied air
80%
60%
80%
Ventilation unit will turn on for 30 min-
utes several times a day. At other times,
the ventilation unit is switched off.
Ventilation intensity 20%.
Intensity
of extract air
20%
50%
80%
Set
temperature
20°C
20°C
20°C
20°C
These settings may be changed (see “Control and Settings”).