![Komatsu WA480-8 Operation & Maintenance Manual Download Page 362](http://html1.mh-extra.com/html/komatsu/wa480-8/wa480-8_operation-and-maintenance-manual_1991104362.webp)
1.
Open the engine side cover on the left side of the ma-
chine.
2.
Loosen nut (2) at the top of fuel breather (1) which is loca-
ted left upper of fan guard and remove it.
3.
Turn cover (3) counterclockwise and remove it.
4.
Remove element (4) upwards.
5.
Blow the dry compressed air from the inside of the ele-
ment.
6.
After cleaning, install the element to the breather body.
At that time, install the element in correct direction.
Direct the surface marked (5) towards up and install.
7.
Install cover (3).
8.
Tighten nut (2).
Tightening torque: 10 to 14 Nm {1.0 to 1.4 kgm}
9.
Close the engine side cover.
NOTICE
If the element is dirty or damaged, replace with new
one.
METHOD FOR LUBRICATING REAR FULL-LENGTH FENDER HINGE
If rear full-length fender is hardly opened or closed, lubricate the hinge portion.
MAINTENANCE PROCEDURE
MAINTENANCE
4-38
Summary of Contents for WA480-8
Page 2: ......
Page 19: ...Distributor name Address Phone Fax Service personnel FOREWORD PRODUCT INFORMATION 1 17...
Page 29: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 3...
Page 159: ...SWITCHES 1 ECSS switch 2 Front working lamp switch OPERATION EXPLANATION OF COMPONENTS 3 91...
Page 302: ...Securing position Fixing angle A 61 B 53 C 33 D 38 TRANSPORTATION OPERATION 3 234...
Page 324: ......
Page 397: ...Viewed from the rear side of the machine MAINTENANCE MAINTENANCE PROCEDURE 4 73...
Page 402: ......
Page 403: ...SPECIFICATIONS 5 1...
Page 406: ......
Page 422: ......
Page 423: ...REPLACEMENT PARTS 7 1...
Page 439: ......