2.
Using UP switch (2) or DOWN switch (3) to set the value,
and press ENTER switch (1).
(2) UP switch
Increases the target fuel consumption value by 1 ℓ/h.
(3) DOWN switch
Decreases the target fuel consumption value by 1 ℓ/h.
To cancel, press RETURN switch (4).
The default is 39 ℓ/h.
REMARK
If the target fuel value is increased, the fuel consumption indi-
cated when the ECO gauge is at the maximum is also in-
creased in proportion.
If the target fuel value is decreased, the fuel consumption indi-
cated when the ECO gauge is at the maximum is also de-
creased in proportion.
For the ECO gauge, see “ECO GAUGE (3-43)”.
SWITCH DISPLAY/NON-DISPLAY OF ECO GUIDANCE
Display/non-display of ECO guidance displayed on the stand-
ard screen can be switched.
1.
Select “ECO Guidance Display ” from “Configurations”
menu, then press ENTER switch (1).
OPERATION
EXPLANATION OF COMPONENTS
3-59