PROCEDURE FOR MANUAL STATIONARY REGENERATION
k
k
CAUTION
Exhaust gas temperature may increase higher than the
previous models during the aftertreatment devices regen-
eration. Avoid getting near the exhaust pipe outlet and
around the aftertreatment devices to prevent being burnt.
Also, keep combustible materials away from the exhaust
pipe outlet and around the aftertreatment devices to pre-
vent a fire.
The manual stationary regeneration can be performed while
KDPF soot accumulation pilot lamp (1) is lit.
1.
Move the machine to a safe place and stop it with engine
running.
2.
Check that there is no person or combustible matter
around the machine (particularly in the direction of the ex-
haust gas flow).
3.
Release your foot from the accelerator pedal and set the
directional lever to NEUTRAL position (N).
4.
Set the parking brake switch to ON position (A) and apply
the parking brake.
5.
Press the menu switch to display “Aftertreatment Devices
Regeneration” screen.
6.
Select the manual stationary regeneration, check again safety of the surrounding area and make sure the
area is free from irrelevant people or combustible material, then press ENTER switch.
If the machine needs to be moved again to secure safety, move it to a safe place and repeat the procedure
from step 1.
OPERATION
EXPLANATION OF COMPONENTS
3-137
Summary of Contents for WA380-8
Page 2: ... ...
Page 20: ......
Page 25: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 5 ...
Page 64: ......
Page 391: ...Viewed from the rear side of the machine MAINTENANCE MAINTENANCE PROCEDURE 4 71 ...
Page 395: ...SPECIFICATIONS 5 1 ...
Page 397: ... 1 Value when bucket dump angle is 45 SPECIFICATIONS SPECIFICATIONS 5 3 ...
Page 400: ......
Page 416: ......
Page 417: ...REPLACEMENT PARTS 7 1 ...
Page 424: ......