OPTIONAL POWER SUPPLY OUTLET
You can take out power of 24 V through connectors (1) and (2) at the rear left of the operator's seat.
No.
Con-
nector
No.
At key
OFF
At key ON
When en-
gine is
started
Fuse
Fuse capacity
(1)
FS6
Power
supplied
Power
supplied
Power
supplied
Fuse box A-(7)
10 A
(2)
FS7
Power not
supplied
Power
supplied
Power
supplied
Fuse box A-(12)
20 A
Since the fuse of (2) is also used for the additional front working lamp (if equipped) and beacon lamp (if equip-
ped), prevent that the current consumption of the devices used does not exceed the capacity of the fuse.
FUSE
NOTICE
When replacing the fuse, be sure to turn the starting switch to OFF position and, after confirming that
the system operating lamp is not lit, set the battery disconnect switch key to OFF position.
The fuses protect the electrical component and wiring from burning out.
If the fuse becomes corroded, or looks white powdery, or the fuse is loose in the fuse holder, replace the fuse.
Replace the fuse with the one of the same capacity.
Should the fuse is blown, investigate the cause and take necessary actions.
Inside rear console box
Loosen knobs (1) (2 places), then remove cover (2). Fuse box-
es are A, B, and C inside.
EXPLANATION OF COMPONENTS
OPERATION
3-120
Summary of Contents for WA380-8
Page 2: ... ...
Page 20: ......
Page 25: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 5 ...
Page 64: ......
Page 391: ...Viewed from the rear side of the machine MAINTENANCE MAINTENANCE PROCEDURE 4 71 ...
Page 395: ...SPECIFICATIONS 5 1 ...
Page 397: ... 1 Value when bucket dump angle is 45 SPECIFICATIONS SPECIFICATIONS 5 3 ...
Page 400: ......
Page 416: ......
Page 417: ...REPLACEMENT PARTS 7 1 ...
Page 424: ......