METHOD FOR CHECKING AND REPLACING ALTERNATOR BELT
• Special tools are required for the replacement of the belt. Ask your Komatsu distributor to perform this work.
• Since the auto-tensioner is installed, tension adjustment is not required.
If alternator drive belt shows the following conditions, it must be
replaced. Ask your Komatsu distributor to replace it.
• When vertical flaw (2) that crosses horizontal flaw (1) is
found.
• When a part of the belt has tears (3).
• You do not need to replace the belt when it has only hori-
zontal flaw (4).
EVERY 2000 HOURS MAINTENANCE
Maintenance for every 50, 100, 250, 500, and 1000 hours service should be performed at the same time.
METHOD FOR CHANGING OIL IN HYDRAULIC TANK, CLEANING HYDRAULIC
TANK STRAINER
k
k
WARNING
• Immediately after the engine is stopped, its parts and oil are still very hot and may cause burn in-
jury. Wait for the temperature to go down, and then start the work.
• When removing the oil filler cap, the oil may spout out. Turn it slowly to release the internal pres-
sure, then remove it carefully.
Refill capacity : 142 ℓ
Items to be prepared
• Container to catch drained oil
1.
Remove inspection window (1) of the undercover.
2.
Lower the bucket to the ground with its bottom level, apply
the parking brake, then stop the engine.
3.
Loosen the bolts and remove cover (2).
MAINTENANCE PROCEDURE
MAINTENANCE
4-56
Summary of Contents for WA380-8
Page 2: ... ...
Page 20: ......
Page 25: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 5 ...
Page 64: ......
Page 391: ...Viewed from the rear side of the machine MAINTENANCE MAINTENANCE PROCEDURE 4 71 ...
Page 395: ...SPECIFICATIONS 5 1 ...
Page 397: ... 1 Value when bucket dump angle is 45 SPECIFICATIONS SPECIFICATIONS 5 3 ...
Page 400: ......
Page 416: ......
Page 417: ...REPLACEMENT PARTS 7 1 ...
Page 424: ......