2.
Remove cap (1) at the top of the battery and check the
electrolyte level through electrolyte filler port (2).
3.
If the electrolyte does not reach the sleeve (3), always add
the purified water (e.g. commercially available replenish-
ment water for a battery) so that the level reaches the bot-
tom of the sleeve (UPPER LEVEL line).
• (A) Correct level: Electrolyte level is up to bottom of
sleeve, so surface tension causes electrolyte surface
to bulge and pole plate appears to be warped.
• (B) Low level: Electrolyte level does not reach the bot-
tom of sleeve, so pole plate appears straight and not
to be warped.
4.
When you add the purified water to the cell of cap (1), add
it to other cells as well.
5.
After adding the purified water, tighten cap (1) securely.
REMARK
If the purified water is added to above the bottom of the
sleeve, use a syringe to remove electrolyte. Neutralize the
removed fluid with baking soda (sodium bicarbonate), then
flush it away with a large amount of water. If necessary,
consult your Komatsu distributor or a battery manufacturer.
METHOD FOR CHECKING ELECTROLYTE LEVEL WHEN IT IS POSSIBLE TO
USE INDICATOR TO CHECK ELECTROLYTE LEVEL
If it is possible to use an indicator to check the electrolyte level, follow the instructions given.
METHOD FOR TESTING PARKING BRAKE
1.
On a dry slope (downhill), turn the parking brake switch
from OFF position (B) to ON position (A).
2.
Check that the machine is stopped and held at the current
position.
If any problem is found, ask your Komatsu distributor for
adjustment.
METHOD FOR CHECKING AND ADJUSTING AIR CONDITIONER COMPRESSOR
BELT TENSION
k
k
WARNING
When checking and adjusting the air conditioner compressor belt tension, stop the engine, and display
the warning tag on the work equipment control lever.
MAINTENANCE
MAINTENANCE PROCEDURE
4-45
Summary of Contents for WA380-8
Page 2: ... ...
Page 20: ......
Page 25: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 5 ...
Page 64: ......
Page 391: ...Viewed from the rear side of the machine MAINTENANCE MAINTENANCE PROCEDURE 4 71 ...
Page 395: ...SPECIFICATIONS 5 1 ...
Page 397: ... 1 Value when bucket dump angle is 45 SPECIFICATIONS SPECIFICATIONS 5 3 ...
Page 400: ......
Page 416: ......
Page 417: ...REPLACEMENT PARTS 7 1 ...
Page 424: ......