Move the machine to display the to display “Standard
Screen”.
“Temporary Restoration from Inducement” is deactivated.
Inducement Strategy for abnormalities recurrences within 40 hours
The Urea SCR system continuously monitors its operation conditions and stores information on inappropriate
operations including malfunctions. The stored information is utilized to monitor recurrences of abnormalities,
“Abnormality Recurrence Counter”. “Abnormality Recurrence Counter” is required by the authorities. The recur-
rence monitoring spans 40 hours and it monitors the abnormalities that trigger Inducement other than the
amount of DEF in the tank.
If another abnormality/abnormalities is detected within 40 hours after the previous abnormalities were corrected,
regardless of the level of the previous Inducement and whether the new abnormality/abnormalities is the same
as the previous ones or not, it is judged as a recurrence.
If a recurrence occurs, “Severe Inducement” will be activated.
Inducement in the recurrence resumes counting time at the time when the previous abnormalities were correc-
ted if the previous Inducement is in “ Warning” or “Continuous Warning” or “Low level Inducement”. The alerts
resume the previous Inducement.
If this occurs, utilize “Temporary Restoration from Inducement” and move to the machine to a safe place, and
contact your Komatsu distributor.
The maximum duration of power restoration is 30 minutes and 3 operations are allowed.
To activate “Temporary Restoration from Inducement”, refer to the “Temporary Restoration from Inducement”
section in this manual.
DEF FILTER
DEF filter is an filter element to clean DEF sucked from the
DEF tank by DEF pump, and to supply it to DEF injector.
NOTICE
• The DEF filter element needs to be replaced every
2000 hours. For details of the replacement procedure,
see “METHOD FOR REPLACING DEF FILTER (4-65)”.
• If the machine is operated without DEF filter attached,
or with the filter other than Komatsu genuine parts,
foreign materials may enter into DEF pump and DEF
injector which will cause failure of the machine. Never
operate the machine without DEF filter attached, nor
use the filter other than Komatsu genuine parts.
• DEF filter cannot be flushed. Flushing or regenerating
of it will degrade the performance of DEF filter, and will
contaminate DEF pump and DEF injector which will
cause the failure of the machine. Never reuse the DEF
filter.
KOMTRAX
KOMTRAX equipment may not be mounted on machines for some countries or regions.
EXPLANATION OF COMPONENTS
OPERATION
3-156
Summary of Contents for WA380-8
Page 2: ... ...
Page 20: ......
Page 25: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 5 ...
Page 64: ......
Page 391: ...Viewed from the rear side of the machine MAINTENANCE MAINTENANCE PROCEDURE 4 71 ...
Page 395: ...SPECIFICATIONS 5 1 ...
Page 397: ... 1 Value when bucket dump angle is 45 SPECIFICATIONS SPECIFICATIONS 5 3 ...
Page 400: ......
Page 416: ......
Page 417: ...REPLACEMENT PARTS 7 1 ...
Page 424: ......