LED display
(1) Three-digit LED display: Values and operating state
(2) Pause time
(3) Pump operation
(4) Monitoring of system function by means of an external cycle
switch
(5) Without function
(6) Fault message
Push button switch
(1) Turn on display
Display values and parameters
Set values and parameters
(2) Change between setting and display mode
Confirm values
(3) Actuation of manual lubrication
Clear fault message
Three-digit LED display
During normal operation, the display is off. It is activated by
briefly operating one of the two push buttons.
It is used for displaying current values and preset parameters.
In addition, the display is used for operator prompting during
setting of operating parameters.
Display
Denotation
Explanation
Control function
t = TIMER
PA = PAUSE
The control unit operates as a time
controlled contact maker (TIMER)
and is in the PAUSE state
Part of lubrication cycle
Input and display value in “hours”
c = COUNTER
PA = PAUSE
Attention! Not used
This mode causes a malfunction.
t = TIMER
CO = CONTACT
The control unit operates as a time
controlled contact maker (TIMER)
and is in the pump running time
(CONTACT)
CONTACT = time during which
the pump is delivering
EXPLANATION OF COMPONENTS
OPERATION
3-130
Summary of Contents for WA380-8
Page 2: ... ...
Page 20: ......
Page 25: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 5 ...
Page 64: ......
Page 391: ...Viewed from the rear side of the machine MAINTENANCE MAINTENANCE PROCEDURE 4 71 ...
Page 395: ...SPECIFICATIONS 5 1 ...
Page 397: ... 1 Value when bucket dump angle is 45 SPECIFICATIONS SPECIFICATIONS 5 3 ...
Page 400: ......
Page 416: ......
Page 417: ...REPLACEMENT PARTS 7 1 ...
Page 424: ......