MAINTENANCE
Service procedure
Every 1000 hours service
4-53
Lubricating
0.
1. Using a grease pump, pump in grease through the grease fittings marked by the arrows.
2. After greasing, wipe off any old grease that was pushed out.
(1) Center hinge pin (2 places)
(2) Engine stop solenoid linkage (1 place)
Check tightening parts of turbocharger
0.
Please contact your Komatsu distributor to have the tightening portions checked.
Check play of turbocharger rotor
0.
Please contact your Komatsu distributor to have the rotor play checked.
Check alternator driving belt tension and replacement
0.
Since inspection and replacement of the belt require special tools, contact your Komatsu distributor.
REMARK
The machine is equipped with an auto tensioner, so there is no need to adjust the tension.