![Komatsu PW130ES-6K Operation & Maintenance Manual Download Page 181](http://html.mh-extra.com/html/komatsu/pw130es-6k/pw130es-6k_operation-and-maintenance-manual_1991289181.webp)
PERIODIC REPLACEMENT OF SAFETY CRITICAL PARTS
MAINTENANCE.
180
SAFETY CRITICAL PARTS
No.
Safety critical parts for periodic replacement
Q’ty
Replacement interval
1
Fuel hose (fuel tank - water separator)
1
Every 2 years or 4000 hours which
ever comes sooner.
2
Fuel hose (water separator - engine lift pump
1
3
Fuel hose (engine lift pump - fuel filter)
1
4
Fuel hose (fuel filter - injection pump)
1
5
Spill hose (engine - fuel tank)
1
6
Hydraulic hose (main pump delivery)
1