When manual stationary regeneration is not activated even af-
ter you push the switch F6, return to the normal screen. Then
push the switch F5, and follow the instructions shown on the
screen.
Manual stationary regeneration may continue for over 40 mi-
nutes. Do not operate any screen switches, fuel control dial, etc
before until regeneration is completed.
PROCEDURE FOR SETTING AFTERTREATMENT DEVICES-REGENERATION
DISABLE
If necessary, it is possible to disable automatic regeneration. Also, it is possible to stop regeneration in progress.
Procedures to disable automatic regeneration
1.
When the aftertreatment devices regeneration display (1)
is not lighting on the standard screen, push F6 on the
standard screen.
2.
Use F1 and F2 to select the “Aftertreatment Devices Re-
generation” menu (C) and display the “Aftertreatment Devi-
ces Regeneration” screen.
3.
With regeneration disable highlighted, push function switch
F6 to disable regeneration.
RKA63320
RKA63310
EXPLANATION OF COMPONENTS
OPERATION
3-136
WENAM00130
Summary of Contents for PW118MR-11
Page 2: ......
Page 9: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVEL 1 7 WENAM00130...
Page 22: ...WENAM00130...
Page 25: ...LOCATION OF SAFETY LABELS RKA64590 SAFETY SAFETY LABELS 2 3 WENAM00130...
Page 72: ...WENAM00130...
Page 74: ...GENERAL VIEW MACHINE EQUIPMENT NAME RKA61930 GENERAL VIEW OPERATION 3 2 WENAM00130...
Page 77: ...CONTROLS AND GAUGES NAMES RKA62690 OPERATION GENERAL VIEW 3 5 WENAM00130...
Page 168: ...SWITCHES RKA63060 EXPLANATION OF COMPONENTS OPERATION 3 96 WENAM00130...
Page 328: ...WENAM00130...
Page 412: ...WENAM00130...
Page 413: ...SPECIFICATIONS 5 1 WENAM00130...
Page 445: ...REPLACEMENT PARTS 7 1 WENAM00130...
Page 461: ......
Page 462: ......