1) Remove the screws (1) and remove the cover (2).
2) Loosen the cap of oil filler port (F) gradually to release
the internal pressure.
3) Remove the cap of oil filler port (F).
4) Add oil through the oil filler port (F) until the oil level comes between the levels H and L of sight gauge
(G).
NOTICE
Do not add oil above mark H. This could damage
the hydraulic system and cause oil spillage.
If the oil has been filled past level H. Wait for the
oil to cool down sufficiently, then drain the excess
oil through valve (P). For details, see MAINTE-
NANCE “METHOD FOR DRAINING THE HYDRAUL-
IC OIL TANK”.
REMARK
The oil level will vary depending upon the oil tempera-
ture. Depending on the temperature, refer to the fol-
lowing guidelines:
• Before starting the operation: Around L level
(Oil temperature 10 to 30 °C)
• Normal operation: Around H Level
(Oil temperature 50 to 80 °C)
5) Install the cover (2) and tighten the screws (1).
METHOD FOR CHECKING COOLANT LEVEL, ADDING COOLANT
k
k
WARNING
• Do not open the radiator cap unless it is necessary. When checking the coolant, check it with the
reservoir tank when the engine is cold.
• Immediately after the engine is stopped, the coolant is still hot and the pressure is accumulated in
the radiator. There is a risk of severe burns if the cap is removed in these conditions to check the
coolant level. Always wait for the temperature to decrease, turn the cap slowly to release the pres-
sure, then remove the cap with care.
1.
Open the cover (1)
2.
Check the reservoir tank (2).
If the coolant level is within the range between FULL and
LOW, the coolant amount is at a proper level.
3.
If the coolant level is LOW, proceed as follows.
RKA63520
RKA63650
P
RKA63660
MACHINE OPERATIONS AND CONTROLS
OPERATION
3-154
WENAM00130
Summary of Contents for PW118MR-11
Page 2: ......
Page 9: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVEL 1 7 WENAM00130...
Page 22: ...WENAM00130...
Page 25: ...LOCATION OF SAFETY LABELS RKA64590 SAFETY SAFETY LABELS 2 3 WENAM00130...
Page 72: ...WENAM00130...
Page 74: ...GENERAL VIEW MACHINE EQUIPMENT NAME RKA61930 GENERAL VIEW OPERATION 3 2 WENAM00130...
Page 77: ...CONTROLS AND GAUGES NAMES RKA62690 OPERATION GENERAL VIEW 3 5 WENAM00130...
Page 168: ...SWITCHES RKA63060 EXPLANATION OF COMPONENTS OPERATION 3 96 WENAM00130...
Page 328: ...WENAM00130...
Page 412: ...WENAM00130...
Page 413: ...SPECIFICATIONS 5 1 WENAM00130...
Page 445: ...REPLACEMENT PARTS 7 1 WENAM00130...
Page 461: ......
Page 462: ......