2.
Move any operating lever to display “Standard Screen”.
“Temporary Restoration from Inducement” is deactivated.
INDUCEMENT STRATEGY FOR ABNORMALITIES RECURRENCES WITHIN 40
HOURS
The Urea SCR system continuously monitors its operation conditions and stores information on inappropriate
operations including malfunctions. The stored information is utilized to monitor recurrences of abnormalities,
“Abnormality Recurrence Counter”. “Abnormality Recurrence Counter” is required by the U.S. Environmental
Protection Agency. The recurrence monitoring spans 40 hours and it monitors the abnormalities that trigger In-
ducement other than the amount of DEF in the tank.
If another abnormality/abnormalities is detected within 40 hours after the previous abnormalities were corrected,
regardless of the level of the previous Inducement and whether the new abnormality/abnormalities is the same
as the previous ones or not, it is judged as a recurrence.
If a recurrence occurs, “Severe Inducement” will be activated. If this occurs, utilize “Temporary Restoration from
Inducement” and move to the machine to a safe place, and contact your Komatsu distributor.
The duration of “Severe Inducement” in the recurrence is limited to 30 minutes. If the abnormalities are not cor-
rected while Inducement is in “Severe Inducement (30 minutes)”, Inducement will advance to “Final Inducement”
and engine speed will be fixed to low idle to disable practical machine operation.
Note that although maximum duration of the power restoration is 30 minutes and 3 operations are possible,
whenever Inducement advances to “Final Inducement”, “Temporary Restoration from Inducement” will be turned
off and its function will be held off till all the abnormalities are corrected.
To activate “Temporary Restoration from Inducement”, refer to the “Temporary Restoration from Inducement”
section in this manual.
DEF filter
DEF filter is an filter element to clean DEF sucked from the
DEF tank by DEF pump, and to supply it to DEF injector.
NOTICE
• The DEF filter element needs to be replaced every
2000 hours. For details of the replacement procedure,
see “METHOD FOR REPLACING DEF FILTER (4-75)”.
• If the machine is operated without the DEF filter at-
tached, or with the filter other than Komatsu genuine
parts, foreign materials may enter the DEF pump and
DEF injector which will cause failure of the machine.
Never operate the machine without the DEF filter at-
tached, nor use the filter other than Komatsu genuine
parts.
• The DEF filter cannot be flushed. Flushing or regener-
ating of it will degrade the performance of DEF filter,
and will contaminate DEF pump and DEF injector
which will cause the failure of the machine. Never re-
use the DEF filter.
RKA63411
RKA63420
OPERATION
EXPLANATION OF COMPONENTS
3-147
WENAM00130
Summary of Contents for PW118MR-11
Page 2: ......
Page 9: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVEL 1 7 WENAM00130...
Page 22: ...WENAM00130...
Page 25: ...LOCATION OF SAFETY LABELS RKA64590 SAFETY SAFETY LABELS 2 3 WENAM00130...
Page 72: ...WENAM00130...
Page 74: ...GENERAL VIEW MACHINE EQUIPMENT NAME RKA61930 GENERAL VIEW OPERATION 3 2 WENAM00130...
Page 77: ...CONTROLS AND GAUGES NAMES RKA62690 OPERATION GENERAL VIEW 3 5 WENAM00130...
Page 168: ...SWITCHES RKA63060 EXPLANATION OF COMPONENTS OPERATION 3 96 WENAM00130...
Page 328: ...WENAM00130...
Page 412: ...WENAM00130...
Page 413: ...SPECIFICATIONS 5 1 WENAM00130...
Page 445: ...REPLACEMENT PARTS 7 1 WENAM00130...
Page 461: ......
Page 462: ......