ECO GAUGE
ECO gauge shows the instantaneous fuel consumption.
The instantaneous fuel consumption means the fuel consump-
tion rate at each current moment, which varies with the work
load and engine speed.
When the gauge is in green range A, the instantaneous fuel
consumption is at a good to medium level.
When the gauge is in yellow range B, the instantaneous fuel
consumption is at a bad level.
REMARK
Although there is no abnormality on the machine when the
gauge enters the yellow range, reduce the engine output to a
point where there is no adverse effect on the operation for the
protection of the global environment. Perform energy-saving
operations in the green range. Travel less frequently. It also
helps to save energy. Consider the best way of operation for
saving energy.
FUEL CONSUMPTION GAUGE
Fuel consumption gauge shows the average fuel consumption
of the machine.
(A): Shows the average fuel consumption of a day (from 0:00
a.m. of the day to 0:00 a.m. of the next day).
(B): Shows the split fuel consumption under measurement.
(C): Shows the split fuel consumption while measurement is
stopped.
REMARK
Display on the fuel consumption gauge can be switched be-
tween the average fuel consumption per day and the average
fuel consumption during a selected period (split fuel consump-
tion).
For the procedure for switching the display, see “ENERGY
SAVING GUIDANCE (3-70)”.
DEF LEVEL GAUGE
DEF level gauge indicates the remaining level of DEF.
If the indicator is in green range during operations, it is normal.
If the indicator comes close to (A) of red range during opera-
tion, check and add DEF.
(A) to (B): Red range
(A) to (C): Green range
When the indicator is in red range from (A) to (B), DEF level
caution lamp (1) lights up in red.
If DEF level further decreases after the lamp lights up in red,
the engine power is derated.
When remaining level of DEF cannot be detected, DEF level caution lamp (1) lights up in white.
EXPLANATION OF COMPONENTS
OPERATION
3-42
WENAM00130
Summary of Contents for PW118MR-11
Page 2: ......
Page 9: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVEL 1 7 WENAM00130...
Page 22: ...WENAM00130...
Page 25: ...LOCATION OF SAFETY LABELS RKA64590 SAFETY SAFETY LABELS 2 3 WENAM00130...
Page 72: ...WENAM00130...
Page 74: ...GENERAL VIEW MACHINE EQUIPMENT NAME RKA61930 GENERAL VIEW OPERATION 3 2 WENAM00130...
Page 77: ...CONTROLS AND GAUGES NAMES RKA62690 OPERATION GENERAL VIEW 3 5 WENAM00130...
Page 168: ...SWITCHES RKA63060 EXPLANATION OF COMPONENTS OPERATION 3 96 WENAM00130...
Page 328: ...WENAM00130...
Page 412: ...WENAM00130...
Page 413: ...SPECIFICATIONS 5 1 WENAM00130...
Page 445: ...REPLACEMENT PARTS 7 1 WENAM00130...
Page 461: ......
Page 462: ......