The accumulator is installed to the position shown in the figure.
METHOD FOR CHECKING ACCUMULATOR FUNCTION
k
k
CAUTION
Be sure that no person or obstacle is around the machine before performing the inspection.
Check the nitrogen gas charge pressure as follows.
1.
Place the machine on a firm, level ground.
2.
Hold the work equipment in the maximum reach posture
(arm fully out, bucket fully dumped) at height 1.5 m from
the ground.
3.
Perform the following procedure within 15 seconds.
After the engine stops, the accumulator pressure decreases gradually. You can check only just after the en-
gine stops.
1) Keep the work equipment at the maximum reach pos-
ture, turn the starting switch to OFF position (A), and
stop the engine.
2) Turn the starting switch to ON position (B).