2.
Select the regeneration disable, press switch F6, and the
regeneration stops.
REMARK
The regeneration performed to protect the system may not
be stopped, but this is not a failure.
PROCEDURE FOR CANCEL OF AFTERTREATMENT DEVICES REGENERATION
DISABLE SETTING
k
k
CAUTION
When canceling the regeneration disable, move the machine to a safe place and check that there is no
person or combustible matter around the machine, and start the cancel operation.
1.
When switch F6 is pressed on the standard screen, “After-
treatment Devices Regeneration” screen is displayed.
(If the screen is not displayed, operate switches F1 and F2
to display “Aftertreatment Devices Regeneration” screen.
2.
Select Cancel of the regeneration disable and press switch
F6, and the regeneration disable is canceled.
If soot accumulation level (4) is lit 3 or more, the regenera-
tion is started automatically.
REMARK
• When canceling the regeneration disable, set the lock
lever to LOCK position and set the fuel control dial to
Low idle (MIN) position, then cancel the regeneration
disable.
• The regeneration disable setting is also canceled by
turning the starting switch to OFF position to stop the
engine.
EXPLANATION OF COMPONENTS
OPERATION
3-120
Summary of Contents for PC700LC-11
Page 2: ......
Page 23: ...LOCATION OF SAFETY LABELS 5 SAFETY SAFETY LABELS 2 3...
Page 66: ......
Page 316: ......
Page 396: ......
Page 397: ...SPECIFICATIONS 5 1...
Page 401: ...For 7 6m Boom SPECIFICATIONS SPECIFICATIONS 5 5...
Page 402: ...SPECIFICATIONS SPECIFICATIONS 5 6...
Page 426: ......
Page 427: ...REPLACEMENT PARTS 7 1...
Page 434: ......