![Komatsu PC490LC-11 Operation & Maintenance Manual Download Page 40](http://html1.mh-extra.com/html/komatsu/pc490lc-11/pc490lc-11_operation-and-maintenance-manual_1991270040.webp)
DO NOT GO CLOSE TO HIGH-VOLTAGE CABLES
Do not travel or operate the machine near electric cables. There is a hazard of electric shock, which may cause
serious personal injury or death. On jobsites where the machine may go close to electric cables, always observe
the following.
• Before starting work near electric cables, inform the local
power company of the work to be performed, and ask them
to take the necessary action.
• Even going close to high-voltage cables can cause electric
shock. Always maintain a safe distance (see the table) be-
tween the machine and the electric cable. Check with the
local power company about the voltage of cables and safe
operating procedure before starting operations.
• To prepare for any possible emergencies, wear rubber
shoes and gloves. Lay a rubber sheet on the operator's
seat, and be careful not to touch the chassis with any ex-
posed part of your body.
• Use a signalman to give warning if the machine ap-
proaches too close to the electric cables.
• When performing operations near high voltage cables, pro-
hibit anyone other than related persons to come close to
the machine during operation.
• If the machine should come too close or touch the electric
cable, to prevent electric shock, the operator should not
leave the operator's compartment until it has been confirmed that the electricity has been shut off. Also,
prohibit any other persons to come close to the machine.
ENSURE GOOD VISIBILITY
Although this machine is equipped with mirrors and cameras to ensure good visibility, there are places that can-
not be seen from the operator's seat. Be careful when performing operation.
When driving the machine or performing operations in places with poor visibility, it is dangerous and may cause
serious personal injury or death because it is difficult to check for obstacles and condition of the jobsite. When
driving the machine or performing operations in places with poor visibility, always observe the following.
• Allocate a signalman for jobsite duty if there are areas where the visibility is poor.
• Only one signalman should give signals.
• When working in dark places, turn on the working lamp and headlamps installed to the machine, and set up
additional lighting in the work area if necessary.
• Stop operations if the visibility is poor because of mist, snow, rain, or dust.
• When checking the mirrors installed to the machine, remove all dirt and adjust the angle of the mirror to
ensure good visibility.
• Clean off any dirt from the lens of cameras installed to the machine, and make sure that the camera gives a
clear view.
09801-03002
DANGER
Serious injury or death will occur if
machine or attachments are not kept
away from electric lines.
Maintain a minimum clearance in
accordance with this chart.
Electrocution Hazard
50 kV or Less
50 kV to 200 kV
200 kV to 350 kV
350 kV to 500 kV
500 kV to 750 kV
750 kV to 1,000 kV
3.1 m (10 ft)
4.6 m (15 ft)
6.1 m (20 ft)
7.7 m (25 ft)
10.7 m (35 ft)
13.8 m (45 ft)
VOLTAGE
MIN. DISTANCE
PRECAUTIONS FOR OPERATION
SAFETY
2-26
Summary of Contents for PC490LC-11
Page 2: ...Find manuals at https best manuals com...
Page 3: ...FOREWORD 1 1 Find manuals at https best manuals com...
Page 19: ...LOCATION OF SAFETY LABELS ZZD10413A SAFETY SAFETY LABELS 2 5...
Page 30: ...Caution for straight travel system STS Op tion 20Y 62 A2760 SAFETY LABELS SAFETY 2 16...
Page 41: ...This as a preview PDF file from best manuals com Download full PDF manual at best manuals com...