11. Check that the oil level is between H and L lines on sight gauge (G).
For applicable oils, see “USE OF FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBIENT TEM-
PERATURE (7-6)”.
For the check of oil level and the installation procedure of the oil filler cap, see “METHOD FOR CHECKING
OIL LEVEL IN HYDRAULIC TANK, ADDING OIL (3-147)”.
12. Bleed air from the hydraulic circuit.
For the air bleeding procedure of hydraulic circuit, see “METHOD FOR BLEEDING AIR FROM HYDRAUL-
IC CIRCUIT (4-38)”.
13. Install undercovers (1) and (2).
EVERY 8000 HOURS MAINTENANCE
Maintenance for every 50, 250, 500, 1000, 2000 and 4000 hours service should be performed at the same time.
METHOD FOR REPLACING FUEL SPRAY PREVENTION CAP
Ask your Komatsu distributor for replacement of the fuel spray prevention caps.
EVERY 9000 HOURS MAINTENANCE
Maintenance for every 50, 250, 500, 1000 and 4500 hours service should be performed at the same time.
METHOD FOR REPLACING DEF HOSE
Ask your Komatsu distributor for replacement of the DEF hose.
END OF SERVICE LIFE
• For safe dismantling of the machine at the end of service life, please contact your Komatsu distributor.
MAINTENANCE PROCEDURE
MAINTENANCE
4-80
Summary of Contents for PC360LC-11
Page 2: ......
Page 22: ......
Page 76: ......
Page 344: ......
Page 425: ...SPECIFICATIONS 5 1 ...
Page 429: ...PC360NLC 11 SPECIFICATIONS SPECIFICATIONS 5 5 ...
Page 430: ......
Page 450: ...PC360LC 11 2 Piece Boom PC360NLC 11 2 Piece Boom 2 PIECE BOOM ATTACHMENTS AND OPTIONS 6 20 ...
Page 457: ...ATTACHMENTS AND OPTIONS 17M LONG REACH BOOM AND ARM 6 27 ...
Page 465: ...ATTACHMENTS AND OPTIONS SUPER LONG FRONT BOOM AND ARM 6 35 ...
Page 499: ...REPLACEMENT PARTS 7 1 ...
Page 515: ......