EXPLANATION OF COMPONENTS
OPERATION
3–128
SYSTEM OPERATING LAMP
System operating lamp:PC-AW1Q-043K00A
This lamp (1) indicates that the controller mounted on the
machine is turned ON.
Lamp (1) lights up in green when the controller is turned ON
and goes out in 1 to 2 minutes after the power for the machine
is turned OFF.
Before operating the battery disconnect switch, check that
lamp (1) is turned OFF.
NOTICE
If the battery disconnect switch is turned OFF while this lamp is lighting, the data in the controller may be
lost.
If the data are lost, when the engine is tried to be started next time, "L04" is displayed on the monitor
panel and the engine may not start.
Ask your Komatsu distributor to carry out inspection and repair.
REMARK
Even if the starting switch is in the OFF position, the controller may operate. The lamp lights up at this point, but it
is not a failure.
After the starting switch has been turned OFF, the system operating lamp may remain turned on for a long time.
In such cases, please contact your Komatsu distributor.
Summary of Contents for PC210-10 DEMOLITION BASE SPEC.
Page 2: ......
Page 14: ...PRODUCT INFORMATION FOREWORD 1 12...
Page 75: ...OPERATION GENERAL VIEW 3 5...
Page 159: ...OPERATION EXPLANATION OF COMPONENTS 3 89...
Page 251: ...OPERATION MACHINE OPERATIONS AND CONTROLS 3 181...
Page 332: ...MAINTENANCE SCHEDULE TABLE MAINTENANCE 4 22 26 Close engine hood 1...
Page 392: ...END OF SERVICE LIFE MAINTENANCE 4 82...
Page 393: ...SPECIFICATIONS 5 1 SPECIFICATIONS SPECIFICATIONS ALL 0000 001K04A SPECIFICATIONS...
Page 397: ...SPECIFICATIONS SPECIFICATIONS 5 5 PC210 10...
Page 398: ...SPECIFICATIONS SPECIFICATIONS 5 6 PC210LC 10...
Page 444: ...RECOMMENDED ATTACHMENT OPERATIONS ATTACHMENTS AND OPTIONS 6 46...
Page 445: ...REPLACEMENT PARTS 7 1 REPLACEMENT PARTS Replacement parts ALL 0000 001K16A REPLACEMENT PARTS...
Page 453: ...8 1 INDEX...
Page 457: ...COLOPHON 18...