INSTRUMENTS AND CONTROLS
116
WEAM012101
3.2.12 MAIN FUSE
IMPORTANT
q
Before replacing fuses, be sure to first turn the starting
switch to the OFF position, wait for over one minute, then
switch the battery disconnect switch to OFF and take out
the battery disconnect switch key.
q
If the engine does not start when the start-up key is set to
START, check the mains fuse and replace it, if necessary.
If the starter does not run when the ignition switch is turned to po-
sition START, the fuse (1) may have blown. Open the battery cov-
er on the left hand side of the machine, check the fuse and
replace if necessary. The mains fuse (45A) is located above the
battery. For instructions for opening and closing the battery cover,
see "3.2.8 BATTERY COVER".
NOTE
q
The main fuse is the high-capacity fuse installed to protect the
electric components and the wiring.
3.2.13 12V OUTLET FUSE
IMPORTANT
q
Before replacing fuses, be sure to first turn the starting
switch to the OFF position, wait for over one minute, then
switch the battery disconnect switch to OFF and take out
the battery disconnect switch key.
The fuse (2), with 12V power outlet protection, is fixed to the horn
wiring located on the machine rear left side.
Loosen the screws (3) and remove the cover to access the fuse.
Always replace the fuse with one of the same capacity.
10A fuse capacity
Summary of Contents for PC18MR-3
Page 2: ......
Page 16: ...14 THIS PAGE WAS INTENTIONALLY LEFT EMPTY...
Page 24: ...22 PAGE INTENTIONALLY LEFT BLANK...
Page 25: ...SAFETY AND ACCIDENT PREVENTION 23...
Page 78: ...76 PAGE INTENTIONALLY LEFT BLANK...
Page 79: ...THE MACHINE AND ITS OPERATIONS 77...
Page 192: ...190 PAGE INTENTIONALLY LEFT BLANK...
Page 193: ...MAINTENANCE 191...
Page 255: ...TECHNICAL SPECIFICATIONS 253...
Page 263: ...AUTHORISED OPTIONAL EQUIPMENT 261...
Page 282: ...280 THIS PAGE WAS INTENTIONALLY LEFT EMPTY...
Page 283: ......
Page 284: ...2010 KOMATSU UTILITY EUROPE S p A All Rights Reserved Printed in Europe 06 2010...