PROCEDURE FOR MANUAL STATIONARY REGENERATION
k
k
CAUTION
• Exhaust gas temperature may increase higher than the previous models during the aftertreatment
devices regeneration.
Stay away from the exhaust pipe outlet to prevent yourself from getting burnt.
Also, keep combustible materials away from the exhaust pipe outlet to prevent a fire.
• For the machines equipped with dump body heating specification, the dump body becomes highly
heated during the aftertreatment devices regeneration.
Stay away from the dump body to prevent yourself from getting burnt.
• Do not leave the operator's seat during the aftertreatment devices regeneration.
The manual stationary regeneration can be performed while
KDPF soot accumulation caution lamp (1) is lit.
REMARK
• On this machine, the manual stationary regeneration can
be performed when soot accumulation level is “1” or
above.
• If there is a failure of which action level is “L02” or above,
or the fuel level caution lamp is lit, the manual stationary
regeneration cannot be performed.
1.
Move the machine to a safe place and stop it with engine
running.
2.
Check that there is no person or combustible matter around the machine (particularly in the direction of the
exhaust gas flow).
3.
Release the accelerator pedal.
4.
Place gear shift lever to NEUTRAL position (N).
OPERATION
EXPLANATION OF COMPONENTS
3-125
Summary of Contents for HM400-5
Page 2: ......
Page 23: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 5 ...
Page 24: ...SAFETY LABELS SAFETY 2 6 ...
Page 60: ......
Page 322: ......
Page 409: ...SPECIFICATIONS 5 1 ...
Page 411: ...SPECIFICATIONS SPECIFICATIONS 5 3 ...
Page 412: ......
Page 413: ...ATTACHMENTS AND OP TIONS Before reading this chapter read and understand the SAFETY 6 1 ...
Page 430: ......
Page 431: ...REPLACEMENT PARTS 7 1 ...