REMARK
During the manual stationary regeneration, idle speed is set rather high.
• The progress of the manual stationary regeneration performed when soot is accumulated can be
checked by the number of lighting lamps of the soot accumulation level (3).
The manual stationary regeneration starts at soot accumulation level “4” or higher and finishes when all
the level lamps go out.
• The manual stationary regeneration for protection of the system may start even when the soot accumu-
lation level is “0” to “3”.
In this case, the soot accumulation level may not decrease, but this is not a failure.
The progress is not displayed on the machine monitor during this regeneration. It is completed in ap-
proximately 10 minutes.
• If the accelerator pedal or gear shift lever is operated, or the parking brake is released during the man-
ual stationary regeneration, the regeneration is stopped automatically.
Release the accelerator pedal, return the gear shift lever to NEUTRAL position (N), apply the parking
brake, and then repeat the procedure from step 7.
• If the machine needs to be moved during the manual stationary regeneration, stop the regeneration
temporarily and move the machine by referring to the aftertreatment devices regeneration disable and
cancel procedures described below.
When restarting the manual stationary regeneration, secure the safety of the machine and around it,
then cancel the regeneration disable.
9.
After the manual stationary regeneration is completed, the screen automatically returns to the standard
screen.
PROCEDURE FOR AFTERTREATMENT DEVICES REGENERATION DISABLE
SETTING
If there is combustible material around the machine and the active regeneration that increases the exhaust tem-
perature must not be performed, the automatic active aftertreatment devices regeneration can be disabled.
Also, the regeneration in progress can be stopped.
NOTICE
While regeneration is disabled, the caution lamp (2) for
KDPF soot accumulation remains on as soot accumulates.
In this condition, move the machine to a safe area and per-
form manual stationary regeneration.
Otherwise, it may cause failure of aftertreatment devices
or the engine.
WHILE REGENERATION IS NOT BEING PERFORMED: SETTING PROCEDURE
FOR REGENERATION DISABLE
(When the aftertreatment devices regeneration display is not lit on the standard screen)
1.
Press the menu switch on the standard screen.
OPERATION
EXPLANATION OF COMPONENTS
3-139
Summary of Contents for HD325-8
Page 2: ......
Page 13: ...FOREWORD INTRODUCTION 1 11 ...
Page 25: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 3 ...
Page 26: ...SAFETY LABELS SAFETY 2 4 ...
Page 340: ......
Page 424: ......
Page 425: ...SPECIFICATIONS 5 1 ...
Page 429: ...ATTACHMENTS AND OP TIONS Before reading this chapter read and understand the SAFETY 6 1 ...
Page 447: ...REPLACEMENT PARTS 7 1 ...
Page 463: ......