For details, see“METHOD FOR INSTALLING HYDRAULIC TANK OIL FILLER CAP (3-153)”.
METHOD FOR CHECKING AND RELEASING NITROGEN GAS CHARGE PRES-
SURE IN ACCUMULATOR (FOR CONTROL CIRCUIT)
k
k
WARNING
The accumulator is charged with high-pressure nitrogen gas, so improper operation may cause an ex-
plosion, which will lead to serious injury or death. For handling, always observe the following.
• The pressure in the hydraulic circuit cannot be completely removed. When removing the hydraulic
equipment, do not stand in the direction that the oil spurts out when performing the operation. In
addition, loosen the bolts slowly when performing the work.
• Do not disassemble it.
• Do not bring open flame close to it or do not dispose of it in fire.
• Do not perform drilling, welding or flame-cutting.
• Do not hit or roll it, or subject it to any impact.
• When disposing of it, the gas must be released. Ask your Komatsu distributor to have this work per-
formed.
NOTICE
If the nitrogen gas charge pressure in the accumulator is low and operations are continued, it becomes
impossible to release the remaining pressure inside the hydraulic circuit if a failure occurs on the ma-
chine.
FUNCTION OF ACCUMULATOR
The accumulator has function of storing the pressure of the control circuit in it. Even after the engine is stopped,
the control circuit can be operated as long as the accumulator functions normally, so the following actions are
possible.
• When the control lever is operated in the direction to lower the work equipment, the work equipment goes
down under its own weight.
• Release the pressure from the hydraulic circuit.
The accumulator is installed to the position shown in the figure.
METHOD FOR CHECKING ACCUMULATOR FUNCTION
k
k
CAUTION
When performing the inspection, check first that there is no person or obstacle in the surrounding area.
Check the nitrogen gas charge pressure as follows.
1.
Place the machine on a flat ground.
MAINTENANCE PROCEDURE
MAINTENANCE
4-74
Summary of Contents for HB365LC-3
Page 2: ......
Page 25: ...LOCATION OF SAFETY LABELS 5 SAFETY SAFETY LABELS 2 5...
Page 348: ......
Page 436: ......
Page 437: ...SPECIFICATIONS 5 1...
Page 441: ...HB365LC 3 SPECIFICATIONS SPECIFICATIONS 5 5...
Page 442: ...HB365NLC 3 SPECIFICATIONS SPECIFICATIONS 5 6...
Page 489: ...REPLACEMENT PARTS 7 1...
Page 505: ......