PROCEDURE FOR MANUAL STATIONARY REGENERATION
The manual stationary regeneration can be performed while
the regeneration performance caution lamp (1) is lit.
During the manual stationary regeneration, engine speed may
increase when the engine is running at low idle.
1.
Move the machine to a safe place and stop it while the en-
gine is running.
2.
Check that there is no person or combustible matter
around the machine (particularly in the direction of the ex-
haust gas flow).
3.
Operate the operating portion (g) of the lock lever to set it
to LOCK position (L).
4.
Set the fuel control dial to Low idle (MIN) position.
5.
Press the switch F6 to display “Aftertreatment Devices Re-
generation” screen (C).
6.
Select the Manual Stationary Regeneration, then press the
switch F6.
After switch F6 is pressed in step 6., the screen shown in the
figure may be displayed. Check that the engine is running nor-
mal, the lock lever is in LOCK position (L), and the fuel control
dial is in low idle position (MIN), then press the switch F6.
EXPLANATION OF COMPONENTS
OPERATION
3-122