MAINTENANCE
MAINTENANCE PROCEDURE
4-69
EVERY 2000 HOURS MAINTENANCE
4
Maintenance for every 10, 100, 250, 500, and 1000 hours of service should be performed at the same time.
CHANGE OIL IN FINAL DRIVE CASE
4
WARNING
q
The parts and oil are at high temperature immediately after the engine is stopped, and may cause seri-
ous burns. Wait for the temperature to go down before starting the operation.
q
If there is still pressure remaining inside the case, the oil or plug may fly out.
Loosen the plug slowly to release the pressure.
q
Refill capacity: Each 20 liters
q
Prepare a handle.
1.
Set the TOP mark at the top, with the TOP mark and plug
(P) perpendicular to the ground surface.
2.
Remove plugs (P) and (F) with the handle and drain the oil.
REMARK
Check the O-rings in the plugs for damage. If necessary,
replace with new ones.
3.
Tighten plug (P).
4.
Add oil through the hole of plug (F).
5.
When the oil overflows from the hole of plug (F), install plug
(F).
Tightening torque of plugs (P) and (F) : 68.6 ± 9.8 N·m
(7 ± 1 kgf·m)
When the oil overflows from the hole of plug (F), install plug
(F). Tighten plugs (P) and (F).
Tightening torque of plugs (P) and (F) : 68.6 ± 9.8 N·m
(7 ± 1 kgf·m)
Summary of Contents for Galeo PC800LC-8
Page 2: ......
Page 3: ...FOREWORD 11 ...
Page 16: ...PRODUCT INFORMATION FOREWORD 1 14 ...
Page 24: ...CONTENTS 1 22 ...
Page 29: ...SAFETY SAFETY LABELS 2 5 LOCATION OF SAFETY LABELS 2 ...
Page 64: ...SAFETY MAINTENANCE INFORMATION SAFETY 2 40 ...
Page 220: ...TROUBLES AND ACTIONS OPERATION 3 156 ...
Page 301: ...SPECIFICATIONS 15 ...
Page 304: ...SPECIFICATIONS SPECIFICATIONS 5 4 ...
Page 313: ...INDEX 17 ...
Page 314: ...INDEX 7 2 ...
Page 317: ...COLOPHON 18 ...