RECOMMENDED FUEL, COOLANT, AND LUBRICANT
MAINTENANCE
4-12
RECOMMENDED FUEL, COOLANT, AND LUBRICANT
4
q
Komatsu genuine oils are adjusted to maintain the reliability and durability of Komatsu construction equipment
and components.
In order to keep your machine in the best conditioner for long periods of time, it is essential to follow the
instructions in this Operation and Maintenance Manual.
q
Failure to follow these recommendations may result in shortened life or excess wear of the engine, power
train, cooling system, and/or other components.
q
Commercially available lubricant additives may be good for the machine, but they may also cause harm.
Komatsu does not recommend any commercially available lubricant additive.
q
Use the oil recommended according to the ambient temperature in the chart below.
q
Specified capacity means the total amount of oil including the oil in the tank and the piping. Refill capacity
means the amount of oil needed to refill the system during inspection and maintenance.
q
When starting the engine in temperatures below 0°C, be sure to use the recommended multi-grade oil, even if
the ambient temperature may become higher during the course of the day.
q
If the machine is operated at a temperature below -20°C, a separate device is needed, so consult your
Komatsu distributor.
q
When the fuel sulfur content is less than 0.2%, change the engine oil according to the period inspection table
given in this Operation and Maintenance Manual.
If the fuel sulfur content is more than 0.2%, change the oil according to the following table.
* If using these fuels, serious troubles may occur because of early deterioration of engine oil or early wear of
engine internal parts. If using them by necessity for local situations, be sure to inform customers about the follow-
ing.
1) Be sure to check Total Basic Number (TBN) of oil frequently by TBN handy checker etc., and change oil
based on the result.
2) Always be aware that oil change interval is extremely shorter than standard.
3) Be sure to carry out periodic engine inspection by distributor's expert since change interval of periodic
replacement parts and overhaul interval are also shorter.
Sulfur content (%)
Oil change interval
Less than 0.2 %
500 hours
0.2 to 0.5 %
250 hours
0.5 and up
Not recommendable (*)
Summary of Contents for Galeo PC800LC-8
Page 2: ......
Page 3: ...FOREWORD 11 ...
Page 16: ...PRODUCT INFORMATION FOREWORD 1 14 ...
Page 24: ...CONTENTS 1 22 ...
Page 29: ...SAFETY SAFETY LABELS 2 5 LOCATION OF SAFETY LABELS 2 ...
Page 64: ...SAFETY MAINTENANCE INFORMATION SAFETY 2 40 ...
Page 220: ...TROUBLES AND ACTIONS OPERATION 3 156 ...
Page 301: ...SPECIFICATIONS 15 ...
Page 304: ...SPECIFICATIONS SPECIFICATIONS 5 4 ...
Page 313: ...INDEX 17 ...
Page 314: ...INDEX 7 2 ...
Page 317: ...COLOPHON 18 ...