MAINTENANCE PROCEDURE
MAINTENANCE
4-20
Checking
4
If air cleaner clogging monitor (1) of the monitor panel flashes,
clean the air cleaner element.
Replacing
q
Replacing element, O-ring
If one year has passed since installing the element or if air
cleaner clogging monitor (1) on the monitor panel flashes
immediately after the element is cleaned, replace the outer
element, inner element, and O-ring.
q
Replacing evacuator valve
Replace it if it is damaged or the rubber is markedly
deformed.
Cleaning Outer Element
4
NOTICE
Before and after cleaning the element, do not leave or keep it in direct sunlight.
1.
Open the engine hood at the front side of the machine,
remove 6 hooks (2), then remove cover (3).
NOTICE
q
Never remove the inner element (6). It will allow dirt to
enter and cause failure of the engine.
q
Do not use a screwdriver or other tool.
2.
Hold the outer element (5), rock it lightly up and down and
to the left and right, and rotate the element to the left and
right to pull it out.
3.
When the outer element (5) has been removed, check that
the inner element has not come out of position and is not at
an angle. If is is at an angle, insert your hand and push it in
straight.
4.
After removing the outer element (5), cover the inner ele-
ment (6) with a clean cloth or tape to prevent dirt or dust
from entering.
5.
Wipe off or brush off the dirt stuck to cover (3) and the
inside of the air cleaner body (7).
Summary of Contents for Galeo PC800LC-8
Page 2: ......
Page 3: ...FOREWORD 11 ...
Page 16: ...PRODUCT INFORMATION FOREWORD 1 14 ...
Page 24: ...CONTENTS 1 22 ...
Page 29: ...SAFETY SAFETY LABELS 2 5 LOCATION OF SAFETY LABELS 2 ...
Page 64: ...SAFETY MAINTENANCE INFORMATION SAFETY 2 40 ...
Page 220: ...TROUBLES AND ACTIONS OPERATION 3 156 ...
Page 301: ...SPECIFICATIONS 15 ...
Page 304: ...SPECIFICATIONS SPECIFICATIONS 5 4 ...
Page 313: ...INDEX 17 ...
Page 314: ...INDEX 7 2 ...
Page 317: ...COLOPHON 18 ...