OPERATION
MACHINE OPERATIONS AND CONTROLS
3-93
2.
Set fuel control dial (2) to the low idling (MIN) position.
3.
Turn the key in starting switch (3) to ON position (B).
If the ambient temperature is low, the preheating monitor
lights up and automatic preheating is carried out. Keep the
key in starting switch (3) at the ON position until the pre-
heating monitor goes out.
The time that the preheating monitor stays lighted up depends
on the ambient temperature as shown in the table on the right.
4.
If the preheating monitor does not light up, or it lights up
and then goes out to inform that the engine preheating has
been completed, turn the key in starting switch (3) to the
START position (C) and start the engine.
REMARK
If the ambient temperature is low, the engine may not start
even when the key in the starting switch (3) is kept at the
START position for 20 seconds. If this happens, wait for at
least 2 minutes, then start again from the beginning.
5.
After the engine starts, release the key in starting switch
(3). The key will automatically return to the ON position (B).
Ambient temperature
Lighting time
- 5 °C
20 seconds
- 10 °C
25 seconds
- 20 °C
40 seconds
Summary of Contents for Galeo PC800LC-8
Page 2: ......
Page 3: ...FOREWORD 11 ...
Page 16: ...PRODUCT INFORMATION FOREWORD 1 14 ...
Page 24: ...CONTENTS 1 22 ...
Page 29: ...SAFETY SAFETY LABELS 2 5 LOCATION OF SAFETY LABELS 2 ...
Page 64: ...SAFETY MAINTENANCE INFORMATION SAFETY 2 40 ...
Page 220: ...TROUBLES AND ACTIONS OPERATION 3 156 ...
Page 301: ...SPECIFICATIONS 15 ...
Page 304: ...SPECIFICATIONS SPECIFICATIONS 5 4 ...
Page 313: ...INDEX 17 ...
Page 314: ...INDEX 7 2 ...
Page 317: ...COLOPHON 18 ...