7.
On “As-built Control” screen, press “Ok”.
The screen returns to the main window.
BLADE CONTROL
METHOD FOR SETTING AUTOMATIC BEST-FIT BLADE CONTROL
When the automatic best-fit blade control is used, 3DMC uses the whole blade edge as reference elevation.
When there is a break line (a broken portion or a sharply changing portion of topography) in the surface, use the
automatic best-fit blade control to perform finish leveling accurately.
1.
On the main window, press “iB logo key” and display the
main menu.
2.
On “Control” menu, press “Blade control...” and select.
3.
On “Blade Control” screen, check “Best-fit (whole blade)”.
4.
Press “Ok”.
METHOD FOR SETTING SINGLE POINT CONTROL
When the single point control is used, 3DMC does not use the whole blade edge as a reference elevation but
uses 1 point selected on the blade.
When finish-leveling to a range where the surface is smaller than the blade width, use the single point control.
AJD02629
AJD02630
AJD02631
HANDLE CONTROL BOX
CONTROL MENU
4-39