• Low level Inducement:
The audible alert sounds in short and sharp beeps.
The DEF system caution lamp (1) lights up in red.
Action level “L03” lights up in red at action level display (2)
and stays on.
Press F6 to display the “SCR Information” screen.
“SCR Information” screen message (4): “3 Engine power is
under deration.”
Due to the engine power deration, capability of the ma-
chine will be limited.
Move the machine to the safe place and contact your Ko-
matsu Distributor.
The duration of “Low level Inducement” is 10 hours. The
remaining time (Hours and Minutes) to “Severe Induce-
ment” is displayed in the column (5) of the “SCR Informa-
tion” screen.
In “Severe Inducement”, engine power will be derated fur-
ther.
• Severe Inducement:
The audible alert sounds in continuous beep.
The DEF system caution lamp (1) lights up in red.
Action level “L04” lights up in red (2).
Press F6 to display the “SCR Information” screen.
“SCR Information” screen message (4): “4 Engine power is
under heavy deration.”
Due to the further deration of engine power, capability the
machine will be limited further.
“Severe Inducement” is the final status of Inducement.
Unless all the “SCR system” abnormalities are corrected,
engine performance will be kept derated.
Engine power can be restored temporarily from power derate. If Inducement advances to “Severe Induce-
ment” and it becomes necessary to restore engine power, use the engine power restoration function to
move the machine to a safe place and contact your Komatsu distributor. This engine power restoration
works only when the Inducement status is “Severe Inducement” and relieves back temporarily to the power
deration of “Low level Inducement”. The operator can restore engine power through the machine monitor.
For the engine power restoration procedure, refer to the section of “Temporary Restoration from Induce-
ment” in this manual.
INDUCEMENT STRATEGY WHEN ABNORMALITY IS FOUND IN THE EGR VALVE
SYSTEM BY THE UREA SCR SYSTEM
If any abnormality is detected in the EGR Valve System through the Urea SCR system, the Inducement strategy