![Komatsu D375A-8 Operation & Maintenance Manual Download Page 450](http://html1.mh-extra.com/html/komatsu/d375a-8/d375a-8_operation-and-maintenance-manual_1991126450.webp)
PERIODIC REPLACEMENT OF DEFINED LIFE PARTS
For using the machine safely for an extended period of time, you must periodically replace the safety and fire
prevention-related parts listed in the table of defined life parts.
Material quality of these parts can change as time passes and they are likely to wear out or deteriorate. Howev-
er, it is difficult to determine the extent of wear or deterioration at the time of periodic maintenance. Hence, it is
required to replace them with new ones regardless of their condition after a certain period of usage. This is im-
portant to ensure that these parts maintain their full performance at all times.
Furthermore, should anything abnormal be found on any of these parts, replace it with a new one even if the
periodic replacement time for the part has not yet arrived.
If any of the hose clamps show deterioration like deformation or cracking, replace the clamps at the same time
as the hoses.
Also perform the following checks with hydraulic hoses which need not to be replaced periodically. Retighten all
loose hoses and replace defective hoses, as required.
When replacing hoses, always replace O-rings, gaskets, and other such parts at the same time.
Have your Komatsu distributor replace the defined life parts.
DEFINED LIFE PARTS LIST
No.
Periodical replacement parts
Replacement interval
1
Fuel system
Fuel hose
Spill hose
Every 2 years or 4000
hours, whichever comes
sooner
2
Work equipment hy-
draulic system
Work equipment pump delivery hose
Work equipment pump LS hose
Hose for hydraulic drive fan
External work equipment hose
•
Blade lift hose
•
Blade tilt hose
•
Ripper lift hose
•
Ripper tilt hose
3
Transmission system Transmission circuit hose
4
Others
PPC accumulator
Seat belt
Every 3 years from start of
usage or 5 years after man-
ufacturing of seat belt,
whichever comes sooner
PERIODIC REPLACEMENT OF DEFINED LIFE PARTS
REPLACEMENT PARTS
7-2
Summary of Contents for D375A-8
Page 2: ......
Page 11: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVELS 1 9...
Page 13: ...Scale interval of the circles is 1 m FOREWORD INTRODUCTION 1 11...
Page 310: ......
Page 394: ......
Page 395: ...SPECIFICATIONS 5 1...
Page 448: ......
Page 449: ...REPLACEMENT PARTS 7 1...
Page 465: ......