• Always check if there is any accumulation of combustible material around the battery, and remove such
combustible material.
METHOD FOR CHECKING FUEL LEVEL, ADDING FUEL
k
k
WARNING
When adding fuel, never spill the fuel or let it overflow. It may cause fire.
If any fuel has spilled, wipe it up completely. If fuel has spilled over soil or sand, remove that soil or
sand.
Fuel is highly flammable and dangerous. Do not bring any open flame close.
1.
Turn the starting switch to ON position.
2.
Check the remaining level by fuel gauge (G) on the moni-
tor panel.
When the fuel gauge pointer reads the red range, the fuel
quantity is 250 ℓ or less.
When the fuel level is low, add fuel.
3.
After checking, turn the starting switch back to OFF posi-
tion.
4.
Check that the engine is stopped.
5.
Open filler cap (F) of the fuel tank and fill the tank with fuel
through filler port.
Fuel tank capacity: 1200 ℓ
REMARK
• When performing operations on slopes, to prevent the
engine from sucking in air, pay careful attention to the
amount of fuel remaining in the tank.
• If the filter of breather (1) is clogged, the pressure in
the tank decreases and fuel may not be supplied nor-
mally to the engine. To prevent this, clean occasional-
ly.
METHOD FOR CHECKING LAMPS OPERATION
1.
Turn the starting switch to ON position (B).
OPERATION
MACHINE OPERATIONS AND CONTROLS
3-137
Summary of Contents for D375A-8
Page 2: ......
Page 11: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVELS 1 9...
Page 13: ...Scale interval of the circles is 1 m FOREWORD INTRODUCTION 1 11...
Page 310: ......
Page 394: ......
Page 395: ...SPECIFICATIONS 5 1...
Page 448: ......
Page 449: ...REPLACEMENT PARTS 7 1...
Page 465: ......