AIR CONDITIONER SWITCH
The air conditioner switch consists of 9 switches.
For explanation of each switch, see “HANDLE AIR CONDI-
TIONER”.
OPERATING MODE SELECTOR SWITCH
The operating mode selector switch is used for switching the
working mode of the engine.
Normally, it is possible to perform all operations in E mode, and
this mode reduces fuel consumption.
Compared with E mode, P mode has more power, but the fuel
consumption increases.
When the starting switch is turned to ON position, the mode
used for the previous operation is selected as the default.
The selected mode is displayed at the top of the screen.
CUSTOMIZE SWITCH
k
k
CAUTION
To ensure safety, always stop the machine before operating the customize mode.
Press the customize switch, and the customize mode selection
screen is displayed.
On the customize mode selection screen, you can freely set
and save the following items.
Item
Contents of setting
Operating mode
Power/Economy
Auto-pitch
Function OFF/ Digging position set only/ Au-
to-pitch
Auto-pitch re-
verse interlock
ON/OFF
Ripper auto-re-
turn
Function OFF/ Lift only/ Lift and Tilt independ-
ent operation/ Lift and Tilt interlocked opera-
tion
Blade fine control ON/OFF
Gear shift mode
Shoe slip control mode/ Rock-bed selection 1
to 5
Manual gear shift mode/ Automatic gear shift
mode
Reverse slow
ON/OFF
Auto shift down*
ON/OFF
*: When manual shift mode is selected
EXPLANATION OF COMPONENTS
OPERATION
3-42
Summary of Contents for D375A-8
Page 2: ......
Page 11: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVELS 1 9...
Page 13: ...Scale interval of the circles is 1 m FOREWORD INTRODUCTION 1 11...
Page 310: ......
Page 394: ......
Page 395: ...SPECIFICATIONS 5 1...
Page 448: ......
Page 449: ...REPLACEMENT PARTS 7 1...
Page 465: ......