2.
Select the regeneration disable, press function switch F6,
and the regeneration stops.
REMARK
The regeneration performed to protect the system may not
be stopped, but this is not a failure.
PROCEDURE FOR CANCEL OF AFTERTREATMENT DEVICES REGENERATION
DISABLE SETTING
k
k
CAUTION
When canceling the regeneration disable, move the machine to a safe place and check that there is no
person or combustible matter around the machine, and start the cancel operation.
1.
When switch F6 is pressed on the standard screen, the Af-
tertreatment Devices Regeneration screen is displayed.
(If the screen is not displayed, operate function switch F1
and F2 and display the Aftertreatment Devices Regenera-
tion screen.
2.
Select the Cancel of the regeneration disable and press
function switch F6, and the regeneration disable is can-
celed.
If soot accumulation level (4) is lit 3 or more, the regenera-
tion is started automatically.
REMARK
• When canceling the regeneration disable, set the
parking brake lever and work equipment lock lever to
LOCK positions and set the fuel control dial to low idle
position, then cancel the regeneration disable.
• The regeneration disable setting is also canceled by
turning the starting switch to OFF position to stop the
engine.
EXPLANATION OF COMPONENTS
OPERATION
3-122