TROUBLESHOOTING
159
3.15.3 IF THE BATTERY HAS RUN DOWN
WARNING
q
When checking or carrying out any operation on the bat-
tery, stop the engine and make sure that the ignition key
is in position « ».
q
The battery produces hydrogen, which may explode. Do
not use naked flames and do not smoke near the bat-
tery, and avoid producing sparks.
q
The battery electrolyte is made of diluted sulphuric acid
that may corrode clothes and even the skin; in case of
contact with this fluid, immediately rinse the involved
part with plenty of water.
If the acid gets into the eyes, immediately rinse with
plenty of water and consult a doctor without delay.
q
When working on the battery, always wear goggles and
gloves.
q
When removing the battery, disconnect first the earth
cable (-); when installing the battery, connect first the
positive cable (+).
q
If a tool makes contact with the positive terminal and the
machine structure at the same time, this may generate
sparks with consequent risk of explosion.
q
Carefully tighten the connection terminals, since false
contacts may generate sparks with consequent risk of
explosion.
RWA01060
1
2
RWA01370
REMOVAL
RWA01800
2
1
RWA01700
INSTALLATION
Summary of Contents for F50003
Page 2: ......
Page 21: ...SAFETY AND ACCIDENT PREVENTION 19 ...
Page 23: ...SAFETY NOISE AND VIBRATION PLATES 21 SW L 1000 kg RKA13490 42N 93 11320 RKAB4740 42N 93 11310 ...
Page 64: ...62 THIS PAGE WAS INTENTIONALLY LEFT EMPTY ...
Page 65: ...THE MACHINE AND ITS OPERATIONS 63 ...
Page 166: ...164 THIS PAGE WAS INTENTIONALLY LEFT EMPTY ...
Page 167: ...MAINTENANCE 165 ...
Page 235: ...TECHNICAL SPECIFICATIONS 233 ...
Page 241: ...TECHNICAL DATA 239 5 1 3 3 LIFTING CAPACITIES TELESCOPIC ARM ...
Page 242: ...240 THIS PAGE WAS INTENTIONALLY LEFT EMPTY ...
Page 243: ...AUTHORISED OPTIONAL EQUIPMENT 241 ...
Page 283: ......
Page 284: ... 2005 KOMATSU UTILITY EUROPE S p A All Rights Reserved Printed in Europe ...