MAINTENANCE PROCEDURE
203
4.9.5 EVERY 2000 HOURS MAINTENANCE
Carry out the maintenance for EVERY 500 HOURS, and EVERY 1000 HOURS SERVICE at the same time.
4.9.5.a
CHANGE OIL IN HYDRAULIC TANK, CLEAN STRAINER
CAUTION
• On machines filled with synthetic biodegradable hydraulic oil type HEES the oil must be changed after
the first 500 hours of operation and successively every 2000 hours, and in any case at least once a year.
WARNING
• When this maintenance is carried out, it is necessary to open (tilt) the floor.
Before starting the operation to open the floor, read the precautions and refer to the explanation for each
part in Section "3.2.12 METHOD OF OPENING (TILTING) FLOOR" when carrying out the operation. Or
ask your Komatsu distributor to carry out the maintenance.
• Immediately after the engine is stopped, the parts and oil are at a high temperature, and will cause bur-
ns. Wait for the temperature to go down before starting the operation.
• When removing the oil filler cap, oil may spurt out, so turn it slowly to release the internal pressure befo-
re removing it.
• Oils, filters, coolants and batteries are considered special waste and must be collected and disposed of
according to the regulations in force.
• Container to catch drained oil: Min. 19 liters capacity
• Refill capacity: 19 liters
• Prepare a handle (for the socket wrench).
1.
Swing the upper structure so that the drain plug under the
hydraulic tank will be between both tracks.
2.
Retract the arm and bucket cylinders, then lower the
boom and put the teeth in contact with the ground.
3.
Lower the blade to the ground.
4.
Set the safety lock lever to the LOCK position and stop
the engine.
NOTE
• For machines equipped with a cab, there is only a safety
lock lever on the left.
Summary of Contents for 15001
Page 2: ......
Page 18: ...16 PAGE INTENTIONALLY LEFT BLANK ...
Page 19: ...SAFETY AND ACCIDENT PREVENTION 17 ...
Page 54: ...52 PAGE INTENTIONALLY LEFT BLANK ...
Page 55: ...THE MACHINE AND ITS OPERATIONS 53 ...
Page 156: ...154 PAGE INTENTIONALLY LEFT BLANK ...
Page 157: ...MAINTENANCE 155 ...
Page 207: ...TECHNICAL SPECIFICATIONS 205 ...
Page 216: ...LIFTING CAPACITIES 214 PAGE INTENTIONALLY LEFT BLANK ...
Page 217: ...AUTHORISED OPTIONAL EQUIPMENT 215 ...
Page 232: ...230 PAGE INTENTIONALLY LEFT BLANK ...
Page 233: ......
Page 234: ... 2005 KOMATSU UTILITY EUROPE S p A All Rights Reserved Printed in Europe ...