Vers. 111422
51
(4)
MIN TIME
The MIN TIME function makes the screwing result NOK (error) if the target torque or
angle is reached before the set minimum time.
ON
: “Below minimum time” error will be displayed if target torque or angle is reached
before the set minimum time, counting from the moment the lever is pressed or a
remote start signal is received.
OFF
: this functionality is disabled.
(5)
MAX TIME
The MAX TIME function makes the screwing result NOK (error) if the target torque or
angle is not reached before the set maximum time.
ON
: “Over maximum time” error will be displayed if target torque or angle is not
reached before the set maximum time, counting from the moment the lever is pressed or
a remote start signal is received.
OFF
: this functionality is disabled.
(6)
PREVAILING TORQUE
The PREVALING TORQUE function makes the screwdriver work at maximum torque
for a set time period or angle selected.
WARNING:
This function is useful for applications where the prevailing torque is
higher than the final target torque (for example self-tapping screws or locknuts). Please
use this function with utmost attention because an incorrect use can damage both the
assembly and the screwdriver!
The time is counted from the moment the lever is pressed or a remote start signal is
received.
The angle is counted in accordance with the
This function can be overlapped with the RAMP function.
The SPEED setting is respected during the prevailing torque phase.
If the torque measured during the prevailing torque time exceeds the maximum torque
achievable by the screwdriver, in other words, if the screwdriver stops turning during
the prevailing torque phase, “Error pvt time” will be displayed.
If OFF, this functionality is disabled.
(7)
RUNNING TORQUE
The RUNNING TORQUE function makes the screwdriver
add (compensate)
the peak
or average torque measured during the set window to the final target torque, in real
time. This function is required in select aerospace and helicoil application, where a fixed
“clamping torque” is to be applied on top of a variable “running torque” (“friction
torque”) encountered during the rundown.
This function can only be activated in Torque Target mode (not in Angle Target mode).
Refer to the
Off
: the function is not active.
Angle
: the running torque is measured within the angle window selected, counted in
accordance with the
Time
: the running torque is measured within the time window selected, starting from
the moment the screwdriver lever (or remote lever command) is pressed.
Summary of Contents for 033001
Page 1: ...KDU NT and KDS NT Torque range 5 70 cNm 7 100 ozfin OPERATOR MANUAL Patent pending...
Page 13: ...Vers 111422 13 Threaded M3 fixturing holes side holes on CA models only...
Page 44: ...Vers 111422 44 PROGRAMS menu tree...
Page 45: ...Vers 111422 45...
Page 46: ...Vers 111422 46...
Page 47: ...Vers 111422 47...
Page 58: ...Vers 111422 58 SEQUENCE SETTINGS menu tree...
Page 68: ...Vers 111422 68 USB menu tree...
Page 72: ...Vers 111422 72 Pinout CN5...
Page 83: ...Vers 111422 83 EXPLODED VIEW KDS NT70 KDS NT70 HM...
Page 84: ...Vers 111422 84...
Page 85: ...Vers 111422 85...
Page 86: ...Vers 111422 86 SPARE PARTS KDS NT70 KDS NT70 HM Lever Kit HM Half Moon model...
Page 87: ...Vers 111422 87 EXPLODED VIEW KDS NT70CA KDS NT70CA HM...
Page 88: ...Vers 111422 88 SPARE PARTS KDS NT70 KDS NT70 HM...