8.9.5.5 Feedback Connector X41 (SFA, accessory)
SFA (
S
mart
F
eedback
A
dapter) converts conventional feedback signals to a 2-wire serial signal. SFA can be
mounted to a top hat rail EN50022–35×7.5 (or EN50022–35×15) or laid into the cable duct.
SFA adds a 15 pole HD SubD female connector X41 to the system for connection of a Kollmorgen motor feed-
back cable (see regional
Accessories Manual
).
Sub-D high density 15 pin, female
0.5 m shielded cable with 3 flying leads for connection to X1 or X2
Input for Electronic Gearing, (
Connected feedback must be set in WorkBench
Use Kollmorgen feedback cables
Output for encoder emulation (EEO3/EEO4), (
Master-Slave (
Connect the three flying leads of the SFA cable to X1 (FB1, EEO3) or X2 (FB2, EEO4) :
X41 Pin
SFD
Resol-
ver
BiSS
B
EnDAT
2.1
EnDAT
2.2
Hiper-
face
Sine/
Cos
Sine/
Cos
+Hall
Incr.
Enc.
Incr.
Enc.
+Hall
Hall
Smart
Abs
Step/
Dir
CW/
CCW
1
-
-
-
-
-
-
-
Hall U
-
Hall U Hall U
-
-
-
2
-
-
CLK+ CLK+
CLK+
-
-
Hall V
-
Hall V Hall V
-
Step+ CW+
3
-
-
CLK-
CLK-
CLK-
-
-
Hall W
-
Hall W Hall W
-
Step-
CW-
4
SEN+
-
SEN+ SEN+
SEN+
▌
SEN+ SEN+
SEN+
SEN+
-
SEN+
-
-
5
SEN-
-
SEN- SEN-
SEN-
SEN- SEN-
SEN-
SEN-
-
SEN-
-
-
6
COM+ R1 Ref+ DAT+ DAT+
DAT+ DAT+ Zero+ Zero+
Zero+
Zero+
-
SD+
Dir+ CCW+
7
COM- R2 Ref- DAT-
DAT-
DAT-
DAT- Zero- Zero-
Zero-
Zero-
-
SD-
Dir-
CCW-
8
-
Thermal control (+)
9
-
Thermal control (-)
10
+5 V
-
+5 V
+5 V
+5 V
8 to 9
V
+5 V
+5 V
+5 V
+5 V
+5 V
+5 V
+5 V
+5 V
11
0 V
-
0 V
0 V
0 V
0 V
0 V
0 V
0 V
0 V
0 V
0 V
0 V
0 V
12
-
S1 SIN+
A+
A+
-
SIN+
A+
A+
A+
A+
-
-
-
-
13
-
S3 SIN-
A-
A-
-
SIN-
A-
A-
A-
A-
-
-
-
-
14
-
S2 COS+
B+
B+
-
COS+
B+
B+
B+
B+
-
-
-
-
15
-
S4 COS-
B-
B-
-
COS-
B-
B-
B-
B-
-
-
-
-
CLK = CLOCK, DAT = DATA, SEN = SENSE
AKD2G-S Installation, Safety 1 | 8 Electrical Installation
Kollmorgen | kdn.kollmorgen.com | Beta, December 2018
89