7.2 Ambient Conditions, Ventilation, and Mounting Position
Storage
Transport
Surrounding air tem-
perature in operation
0 to +40 °C under rated conditions
+40 to +55 °C with continuous current derating 4 % per Kelvin
Humidity in operation
Relative humidity 5 to 85%, no condensation, class 3K3
Site altitude
Up to 1000 meters above mean sea level without restriction
1,000 to max. 2,500 meters above mean sea level with power
derating 1.5%/100 m
Pollution level
Pollution level 2 as per IEC 60664-1
Vibrations
Class 3M1 according to IEC 60721-3-3
Enclosure protection
IP 20 according to IEC 60529
Mounting position
Vertical, (
Ventilation
Built-in fan (except AKD-x00306 type)
The drive shuts down (fault F234, (
# 202), motor has no
torque) in case of excessively high temperature in the control cab-
inet. Make sure sufficient forced ventilation is supplied within the
control cabinet.
7.3 Mechanical Data
Mechanical data
Units
AKD-
x00306
AKD-
x00606
AKD-x01206
AKD-
x02406
Weight (standard width)
kg
1.1
2
3.7
Weight (extended width)
kg
1.3
2.2
4
Height, without connectors
mm
168
196
248
Height, with connector
mm
200
225
280
Standard Width front/back
mm
54/59
72/78.4
96/100
Extended Width front/back
mm
84/89
91/96
96/100
Depth, without connectors
mm
156
187
228
Depth, with connectors
mm
185
< 215
<265
Mechanical data
Units
AKD-
x00307
AKD-
x00607
AKD-
x01207
AKD-
x02407
AKD-
x04807
Weight (standard width)
kg
2.7
5.3
11.5
Weight (extended width)
kg
2.9
5.5
11.7
Height, without connectors
mm
256
306
385
Height, with connector
mm
290
340
526
Standard Width front/back
mm
65/70
99/105
185/185
Extended Width front/back
mm
95/100
99/105
-
Depth, without connectors
mm
185
228
225
Depth, with connectors
mm
<225
<265
<265