AKD Installation | 9 Electrical Installation
9.12.1 Feedback connector (X10)
Pin SFD
SFD3/
DSL
Resolver
BiSS B
(analog)
BiSS C
(digital)
EnDAT
2.1
EnDAT
2.2
Hiper-
face
Sine
Enc.
+Hall
Incr.
Enc.
+Hall
Hall
Tamagawa
Smart
Abs*
1
-
-
-
-
-
-
-
-
Hall U Hall U Hall U
-
2
-
-
-
CLK+
CLK+
CLK+
CLK+
-
Hall V Hall V Hall V
-
3
-
-
-
CLK-
CLK-
CLK-
CLK-
-
Hall W Hall W Hall W
-
4 SEN+
-
-
SEN+
SEN+ SEN+ SEN+
SEN+
SEN+ SEN+
-
SEN+
5
SEN-
-
-
SEN-
SEN-
SEN-
SEN-
SEN-
SEN- SEN-
-
SEN-
6 COM+ COM+ R1 Ref+
DAT+
DAT+
DAT+
DAT+
DAT+
Zero+ Zero+
-
SD+
7 COM- COM-
R2 Ref-
DAT-
DAT-
DAT-
DAT-
DAT-
Zero-
Zero-
-
SD-
8
-
-
Thermal control (+)
9
-
-
Thermal control (-)
10
+5 V 8 to 9 V
-
+5 V
+5 V
+5 V
+5 V
8 to 9 V
+5 V
+5 V
+5 V
+5 V
11
0 V
0 V
-
0 V
0 V
0 V
0 V
0 V
0 V
0 V
0 V
0 V
12
-
-
S1 SIN+
A+
-
A+
-
SIN+
A+
A+
-
-
13
-
-
S3 SIN-
A-
-
A-
-
SIN-
A-
A-
-
-
14
-
-
S2 COS+
B+
-
B+
-
COS+
B+
B+
-
-
15
-
-
S4 COS-
B-
-
B-
-
COS-
B-
B-
-
-
CLK = CLOCK, DAT = DATA, SEN = SENSE
, *= for AKD with "NB" (rev 8+) only
122
Kollmorgen | kdn.kollmorgen.com | October 2017