AKD PDMM User Guide | 39.8 MOTOR.IDDATAVALID
Description
This parameter is used to configure the motor continuous current.
Related Topics
39.8 MOTOR.IDDATAVALID
General Information
Type
R/O Parameter
Description
Reports the status of the motor mem-
ory.
Units
N/A
Range
N/A
Default
Value
0
Data Type
Integer
See Also
N/A
Start Version M_01-02-00-000
Description
MOTOR.IDDATAVALID reports the status of the motor memory status.
The valid values for this keyword are the following:
Value
Description
0
Error in identification
1
Success in identification
2
Identification in process
3
Identification not started yet
4
Success recognizing feedback, but failed to varify OEM data integ-
rity
Related Topics
39.9 MOTOR.IMID
General Information
Type
R/W
Description
The direct-axis current set point used for induction machine closed-loop con-
trol.
Units
Arms
Range
0 to DRIVE.IPEAK
Default
Value
0
Data Type
Float
Start Version M_01-08-00-000
Description
The value of IL.IMID can be estimated using the motor name plate information.
381
Kollmorgen™ | December 2012
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...