AKD PDMM User Guide | 39.5 MOTOR.BRAKESTATE
General Information
Default
Value
0
Data Type
Integer
See Also
N/A
Start Version M_01-00-00-000
Fieldbus
Index/Subindex Object Start Version
EtherCAT COE and CAN-
open
M_01-00-00-000
Description
This command allows a user to release or apply the motor brake.
0 = Drive controls the brake.
1 = Brake is released.
2 = Brake is applied.
A digital input mode is also used for the same purpose. The two mechanisms
are independent.
The CANopen-object 0x345A sub 1/2 can be used to control the brake state.
See
on kollmorgen.com. (Functionality starts with firmware
1.7.4.0)
Related Topics
39.5 MOTOR.BRAKESTATE
General Information
Type
R/O Parameter
Description
Reads the actual status of the motor
brake.
Units
N/A
Range
Brake released or not present.
Brake applied.
Default
Value
Brake applied or not present.
Data Type
String
See Also
N/A
Start Version M_01-00-00-000
Description
This parameter reads the actual status of the motor brake and can only show two states:
1 = Brake released or not present
2 = Brake applied
Related Topics
379
Kollmorgen™ | December 2012
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...