AKD PDMM User Guide | 31.21 FB1.RESREFPHASE
General Information
See Also
N/A
Start Version M_01-00-00-000
Description
This parameter sets the resolver nominal transformation ratio. It affects the resolver excitation
output amplitude.
The value can be obtained from the resolver data sheet.
Related Topics
31.21 FB1.RESREFPHASE
General Information
Type
NV Parameter
Description
Sets the electrical degrees of phase lag in the
resolver.
Units
electrical degrees
Range
-180 to 180°
Default
Value
-2°
Data Type
Float
See Also
N/A
Start Version M_01-00-00-000
Description
This parameter sets the electrical degrees of phase lag in the resolver.
See the motor resolver datasheet for the value for this parameter .
Related Topics
31.22 FB1.SELECT
General Information
Type
NV Parameter
Description
Sets user entered type or identified type (–1).
Units
N/A
Range
–1, 10, 20, 30, 31, 32, 40, 41, 42
Default
Value
–1
Data Type
Integer
See Also
FB1.IDENTIFIED
Start Version M_01-00-00-000
Fieldbus
Index/Subindex Object Start Version
EtherCAT COE and CAN-
open
/0
M_01-00-00-000
Kollmorgen™ | December 2012
320
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...